Division B Sleep Mode (Power Switch On, No Video Signal)
- (1)
At the conclusion of the On Mode test, initiate the display's Sleep Mode. The method of adjustment shall be documented along with the sequence of events required to reach the Sleep Mode. Power on all test equipment and properly adjust operation range.
- (2)
Allow the display to remain in Sleep Mode until stable power readings are measured. Measurements are considered stable once the wattage reading does not vary more than 1% over a three-minute period. Tester shall ignore the input sync signal check cycle when metering the unit in Sleep Mode.
- (3)
Record the test conditions and test data. The measurement time shall be sufficiently long to measure the correct average value (i.e., not peak or instantaneous power). If the device has different Sleep Modes that can be manually selected, the measurement should be taken with the device in the most energy consumptive of those modes. If the modes are cycled through automatically, the measurement time should be long enough to obtain a true average that includes all modes.